Enter 5DINGO at Checkout for 5% OFF & Free Shipping Australia Wide

{"id":7414062186656,"title":"[2 Pack] DC 6-30V Timer Relay Programmable Delay Relay Module Cycle Timer with LCD Display \/ 5V Micro USB, Smart Home Controller","handle":"2-pack-dc-6-30v-timer-relay-programmable-delay-relay-module-cycle-timer-with-lcd-display-5v-micro-usb-smart-home-controller","description":"\u003ch3\u003e[2 Pack] DC 6-30V Timer Relay Programmable Delay Relay Module Cycle Timer with LCD Display \/ 5V Micro USB, Smart Home Controller\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eThe multifunctional relay control module is designed for\npeople with different timing and control needs. It's perfect for many\napplications from hobby to industrial controls. Specifications: Operating\nvoltage: DC 6V - 30V, supporting micro USB 5V power supply Operating current:\n50mA, static current: 20mA Working temperature: -20—60℃ NO maximum load: \u0026lt; AC\n250V\/10A, \u0026lt; DC 30V\/10A Size: 6.43.81.7cm Operation Modes: P1: Upon signal is\ntriggered(application of input voltage), the relay conducts OP time, then turn\noff. Operate within the OP period as follows. - P1.1: Signal being re-\ntriggered is ignored - P1.2: Signal being re-triggered to reclock - P1.3:\nSignal being re-triggered to reset, the relay contact disconnected, stop\ntiming P2: Feed trigger signal, the relay closed CL time, then conducts OP\ntime. After timing, turn off the relay P3.1: Feed trigger signal, the relay\nconducted OP time, the relay closed CL time, then repeat above actions, re-\ntrigger signal within the timing cycle, the relay contact disconnected, stop\ntiming. The circuit times(LOP) can be set. P3.2: No need to trigger signal\nwhen power on, the relay conducts OP time, the relay closed CL time, then\nrepeat above actions.The circuit times(LOP) can be set. P4: The function of\nremaining signal: the timing will be reset upon signal is triggered, relay\ncontacts stay connected. when no signal, turn off the relay after timing OP.\nDuring the period of timing, the timing will be reset upon signal is re-\ntriggered. Timing Range: 0.1 seconds (min.) ~ 999 minutes (max.) continuously\nadjustable How to choose a timing range: Upon setting the parameter value in\nthe mode selection interface, select the timing range by short pressing the\nSTOP button. XXX. Decimal point at single digit, timing range = 1 second ~ 999\nseconds. XX.X Decimal point at tens digit. timing range = 0.1 second ~ 99.9\nseconds X.X.X. All the decimal points appear, timing range = 1 minute ~ 999\nminutes. For example, if you want to set the OP to 3.2 seconds, then move the\ndecimal point to the tenth digit, the digital tube displays 03.2 Parameter\nexplanation: OP = on time, CL = off time, LOP = cycle times (1 - 999 times,\n\"---\" stands for infinite cycles) These parameters are independent each other,\nwhile they are shared by all operation modes. For example, when the OP(on-\ntime) is set to 5 seconds in P1.1, the user wants P1.2 mode, then enter P1.2\nto set the corresponding parameters, OP will also be 5 seconds. In the main\ninterface (digital tube displays 000), short press SET button, it will show OP\n(CL, LOP) and the corresponding time XXX - If there is only OP (such as mode\nP1.1, P1.2, P1.3) time in the mode, then short press SET button will only\ndisplay OP and the corresponding time. - If there are OP, CL, LOP in the mode\n(such as mode P3.1, P3.2), short press SET button will display OP and\ncorresponding time, CL and corresponding time, LOP and corresponding times.\nAfter setting the operation mode, you can easily view and change the\nparameters by pressing the SET button in the main interface. How to Set\nParameters 1. First of all, determine the working mode of the relay. 2. Upon\nthe working mode of the relay, in the main interface (when the module is\npowered on, it will flash the current working mode - default P1.1 mode, and\nthen enter the main interface) Long press the SET button for 2 seconds and\nrelease to enter the mode selection interface, select and set the mode (P1.1 ~\nP-4) by short pressing the UP and DOWN buttons. 3. Select a setting mode you\nwant (Eg. P3.2), short press SET button to set the parameter. At that time,\nthe parameter you set will flash (OP - ON time, CL - OFF time, LOP - cycle\nnumber). You could adjust the parameter by pressing UP and DOWN button. Long\npress (increase or reduce rapidly) and short press (increase or decrease by 1\nunit) are supported. After setting the parameter, select the position of units\npoint by short pressing “STOP” button to choose a timing range (corresponding\ntime 0.1 seconds~999 minutes). Short press “SET” button to set the next\nparameter of current mode, the progress is as what have mentioned above. 4.\nAfter selecting the mode’s parameter, long press the “SET” button for 2\nseconds and release. The current setting mode will flash and return to the\nmain interface, and the parameter setting is finished. It’s very simple! Main\ninterface: It will appear “000” without decimal points when at “OFF” status,\nwhile appears decimal points clearly at “ON” status. Mode selecting interface:\nLong press “SET” button to set parameter, while long press “SET” button to\nreturn back to the main interface. It’s very simple! Relay Using Mode: 1. ON:\nRelay is allowed to conduct within OP time (on-time). 2. OFF: Relay is banned\nconducting and it is always at closing status. Short pressing “STOP” button in\nthe main interface, you will realize the shift between “ON” and “OFF”. It will\nflash and return to the main interface. (This is acute stop function, one-\nbutton turn on and off the relay) Sleep Mode: 1. C-P sleeping mode: When not\nusing the relay for 5 minutes, the digital tube will turn off the display\nautomatically, and the program will keep working. 2. O-d normal mode: Display\nof digital tube always on. Long press “STOP” button for 2 seconds and release\nto shift the status of C-P and O-d. It will flash and return to the main\ninterface. Package List: 2 x DC 6-30V Timer Relay Module with LED display\n(paper manual not included)\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eMultifunction Timer RelayProgrammable delay modes to control the relay timings, widely used at smart home, industrial control, automatic irrigation, indoor ventilation, protection equipment etc.\u003c\/li\u003e\n \u003cli\u003eLoad RangeOperating voltage: DC 6V - 30V, support micro USB 5V power supply. High level trigger: 3V - 24V. NO(Normally open) maximum load \u0026lt; AC 250V\/10A, \u0026lt; DC 30V\/10A. Timing range: 0.1s ~ 999mins (continuously adjustable).\u003c\/li\u003e\n \u003cli\u003eReverse ProtectionBuilt-in a diode to provide protection against accidental reverse polarity for the circuits.\u003c\/li\u003e\n \u003cli\u003eSleep ModeIf no operation within 5 minutes, the digital tube of the relay board will turn off automatically. Pressing any button can wake it up.\u003c\/li\u003e\n \u003cli\u003eParameter SettingOP(conduction time) \/ CL(off time) \/ LOP(circuit times) can be set individually, and the parameters are mutually independent. All parameters are permanently saved once set. The functions and parameters can be reviewed or changed at a later time.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n","published_at":"2022-06-14T15:20:57+10:00","created_at":"2022-06-14T15:21:03+10:00","vendor":"Valefod","type":"Electrical","tags":["dingo"],"price":11300,"price_min":11300,"price_max":11300,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":42194432295072,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B085TL38NH","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"[2 Pack] DC 6-30V Timer Relay Programmable Delay Relay Module Cycle Timer with LCD Display \/ 5V Micro USB, Smart Home Controller","public_title":null,"options":["Default Title"],"price":11300,"weight":68,"compare_at_price":null,"inventory_management":null,"barcode":"VA-0190","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/dingoship.com.au\/cdn\/shop\/products\/B085TL38NH.jpg?v=1655252230","\/\/dingoship.com.au\/cdn\/shop\/products\/71CIg0ev8rL.jpg?v=1655184063","\/\/dingoship.com.au\/cdn\/shop\/products\/71ql4Q1qiCL.jpg?v=1655184063","\/\/dingoship.com.au\/cdn\/shop\/products\/81TWfnmd3hL.jpg?v=1655184063","\/\/dingoship.com.au\/cdn\/shop\/products\/71WuHZmSe6L.jpg?v=1655184063","\/\/dingoship.com.au\/cdn\/shop\/products\/71OLdmdRi7L.jpg?v=1655184063","\/\/dingoship.com.au\/cdn\/shop\/products\/71RlT2FYUgL.jpg?v=1655184063"],"featured_image":"\/\/dingoship.com.au\/cdn\/shop\/products\/B085TL38NH.jpg?v=1655252230","options":["Title"],"media":[{"alt":null,"id":24860367650976,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/dingoship.com.au\/cdn\/shop\/products\/B085TL38NH.jpg?v=1655252230"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/dingoship.com.au\/cdn\/shop\/products\/B085TL38NH.jpg?v=1655252230","width":1500},{"alt":null,"id":24854075441312,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/dingoship.com.au\/cdn\/shop\/products\/71CIg0ev8rL.jpg?v=1655184063"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/dingoship.com.au\/cdn\/shop\/products\/71CIg0ev8rL.jpg?v=1655184063","width":1500},{"alt":null,"id":24854075474080,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/dingoship.com.au\/cdn\/shop\/products\/71ql4Q1qiCL.jpg?v=1655184063"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/dingoship.com.au\/cdn\/shop\/products\/71ql4Q1qiCL.jpg?v=1655184063","width":1500},{"alt":null,"id":24854075506848,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/dingoship.com.au\/cdn\/shop\/products\/81TWfnmd3hL.jpg?v=1655184063"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/dingoship.com.au\/cdn\/shop\/products\/81TWfnmd3hL.jpg?v=1655184063","width":1500},{"alt":null,"id":24854075539616,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/dingoship.com.au\/cdn\/shop\/products\/71WuHZmSe6L.jpg?v=1655184063"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/dingoship.com.au\/cdn\/shop\/products\/71WuHZmSe6L.jpg?v=1655184063","width":1500},{"alt":null,"id":24854075572384,"position":6,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/dingoship.com.au\/cdn\/shop\/products\/71OLdmdRi7L.jpg?v=1655184063"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/dingoship.com.au\/cdn\/shop\/products\/71OLdmdRi7L.jpg?v=1655184063","width":1500},{"alt":null,"id":24854075605152,"position":7,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/dingoship.com.au\/cdn\/shop\/products\/71RlT2FYUgL.jpg?v=1655184063"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/dingoship.com.au\/cdn\/shop\/products\/71RlT2FYUgL.jpg?v=1655184063","width":1500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003e[2 Pack] DC 6-30V Timer Relay Programmable Delay Relay Module Cycle Timer with LCD Display \/ 5V Micro USB, Smart Home Controller\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eThe multifunctional relay control module is designed for\npeople with different timing and control needs. It's perfect for many\napplications from hobby to industrial controls. Specifications: Operating\nvoltage: DC 6V - 30V, supporting micro USB 5V power supply Operating current:\n50mA, static current: 20mA Working temperature: -20—60℃ NO maximum load: \u0026lt; AC\n250V\/10A, \u0026lt; DC 30V\/10A Size: 6.43.81.7cm Operation Modes: P1: Upon signal is\ntriggered(application of input voltage), the relay conducts OP time, then turn\noff. Operate within the OP period as follows. - P1.1: Signal being re-\ntriggered is ignored - P1.2: Signal being re-triggered to reclock - P1.3:\nSignal being re-triggered to reset, the relay contact disconnected, stop\ntiming P2: Feed trigger signal, the relay closed CL time, then conducts OP\ntime. After timing, turn off the relay P3.1: Feed trigger signal, the relay\nconducted OP time, the relay closed CL time, then repeat above actions, re-\ntrigger signal within the timing cycle, the relay contact disconnected, stop\ntiming. The circuit times(LOP) can be set. P3.2: No need to trigger signal\nwhen power on, the relay conducts OP time, the relay closed CL time, then\nrepeat above actions.The circuit times(LOP) can be set. P4: The function of\nremaining signal: the timing will be reset upon signal is triggered, relay\ncontacts stay connected. when no signal, turn off the relay after timing OP.\nDuring the period of timing, the timing will be reset upon signal is re-\ntriggered. Timing Range: 0.1 seconds (min.) ~ 999 minutes (max.) continuously\nadjustable How to choose a timing range: Upon setting the parameter value in\nthe mode selection interface, select the timing range by short pressing the\nSTOP button. XXX. Decimal point at single digit, timing range = 1 second ~ 999\nseconds. XX.X Decimal point at tens digit. timing range = 0.1 second ~ 99.9\nseconds X.X.X. All the decimal points appear, timing range = 1 minute ~ 999\nminutes. For example, if you want to set the OP to 3.2 seconds, then move the\ndecimal point to the tenth digit, the digital tube displays 03.2 Parameter\nexplanation: OP = on time, CL = off time, LOP = cycle times (1 - 999 times,\n\"---\" stands for infinite cycles) These parameters are independent each other,\nwhile they are shared by all operation modes. For example, when the OP(on-\ntime) is set to 5 seconds in P1.1, the user wants P1.2 mode, then enter P1.2\nto set the corresponding parameters, OP will also be 5 seconds. In the main\ninterface (digital tube displays 000), short press SET button, it will show OP\n(CL, LOP) and the corresponding time XXX - If there is only OP (such as mode\nP1.1, P1.2, P1.3) time in the mode, then short press SET button will only\ndisplay OP and the corresponding time. - If there are OP, CL, LOP in the mode\n(such as mode P3.1, P3.2), short press SET button will display OP and\ncorresponding time, CL and corresponding time, LOP and corresponding times.\nAfter setting the operation mode, you can easily view and change the\nparameters by pressing the SET button in the main interface. How to Set\nParameters 1. First of all, determine the working mode of the relay. 2. Upon\nthe working mode of the relay, in the main interface (when the module is\npowered on, it will flash the current working mode - default P1.1 mode, and\nthen enter the main interface) Long press the SET button for 2 seconds and\nrelease to enter the mode selection interface, select and set the mode (P1.1 ~\nP-4) by short pressing the UP and DOWN buttons. 3. Select a setting mode you\nwant (Eg. P3.2), short press SET button to set the parameter. At that time,\nthe parameter you set will flash (OP - ON time, CL - OFF time, LOP - cycle\nnumber). You could adjust the parameter by pressing UP and DOWN button. Long\npress (increase or reduce rapidly) and short press (increase or decrease by 1\nunit) are supported. After setting the parameter, select the position of units\npoint by short pressing “STOP” button to choose a timing range (corresponding\ntime 0.1 seconds~999 minutes). Short press “SET” button to set the next\nparameter of current mode, the progress is as what have mentioned above. 4.\nAfter selecting the mode’s parameter, long press the “SET” button for 2\nseconds and release. The current setting mode will flash and return to the\nmain interface, and the parameter setting is finished. It’s very simple! Main\ninterface: It will appear “000” without decimal points when at “OFF” status,\nwhile appears decimal points clearly at “ON” status. Mode selecting interface:\nLong press “SET” button to set parameter, while long press “SET” button to\nreturn back to the main interface. It’s very simple! Relay Using Mode: 1. ON:\nRelay is allowed to conduct within OP time (on-time). 2. OFF: Relay is banned\nconducting and it is always at closing status. Short pressing “STOP” button in\nthe main interface, you will realize the shift between “ON” and “OFF”. It will\nflash and return to the main interface. (This is acute stop function, one-\nbutton turn on and off the relay) Sleep Mode: 1. C-P sleeping mode: When not\nusing the relay for 5 minutes, the digital tube will turn off the display\nautomatically, and the program will keep working. 2. O-d normal mode: Display\nof digital tube always on. Long press “STOP” button for 2 seconds and release\nto shift the status of C-P and O-d. It will flash and return to the main\ninterface. Package List: 2 x DC 6-30V Timer Relay Module with LED display\n(paper manual not included)\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eMultifunction Timer RelayProgrammable delay modes to control the relay timings, widely used at smart home, industrial control, automatic irrigation, indoor ventilation, protection equipment etc.\u003c\/li\u003e\n \u003cli\u003eLoad RangeOperating voltage: DC 6V - 30V, support micro USB 5V power supply. High level trigger: 3V - 24V. NO(Normally open) maximum load \u0026lt; AC 250V\/10A, \u0026lt; DC 30V\/10A. Timing range: 0.1s ~ 999mins (continuously adjustable).\u003c\/li\u003e\n \u003cli\u003eReverse ProtectionBuilt-in a diode to provide protection against accidental reverse polarity for the circuits.\u003c\/li\u003e\n \u003cli\u003eSleep ModeIf no operation within 5 minutes, the digital tube of the relay board will turn off automatically. Pressing any button can wake it up.\u003c\/li\u003e\n \u003cli\u003eParameter SettingOP(conduction time) \/ CL(off time) \/ LOP(circuit times) can be set individually, and the parameters are mutually independent. All parameters are permanently saved once set. The functions and parameters can be reviewed or changed at a later time.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n"}

[2 Pack] DC 6-30V Timer Relay Programmable Delay Relay Module Cycle Timer with LCD Display / 5V Micro USB, Smart Home Controller

In Stock. Leaves warehouse within 2 - 3 business days

113.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

[2 Pack] DC 6-30V Timer Relay Programmable Delay Relay Module Cycle Timer with LCD Display / 5V Micro USB, Smart Home Controller

The multifunctional relay control module is designed for people with different timing and control needs. It's perfect for many applications from hobby to industrial controls. Specifications: Operating voltage: DC 6V - 30V, supporting micro USB 5V power supply Operating current: 50mA, static current: 20mA Working temperature: -20—60℃ NO maximum load: < AC 250V/10A, < DC 30V/10A Size: 6.43.81.7cm Operation Modes: P1: Upon signal is triggered(application of input voltage), the relay conducts OP time, then turn off. Operate within the OP period as follows. - P1.1: Signal being re- triggered is ignored - P1.2: Signal being re-triggered to reclock - P1.3: Signal being re-triggered to reset, the relay contact disconnected, stop timing P2: Feed trigger signal, the relay closed CL time, then conducts OP time. After timing, turn off the relay P3.1: Feed trigger signal, the relay conducted OP time, the relay closed CL time, then repeat above actions, re- trigger signal within the timing cycle, the relay contact disconnected, stop timing. The circuit times(LOP) can be set. P3.2: No need to trigger signal when power on, the relay conducts OP time, the relay closed CL time, then repeat above actions.The circuit times(LOP) can be set. P4: The function of remaining signal: the timing will be reset upon signal is triggered, relay contacts stay connected. when no signal, turn off the relay after timing OP. During the period of timing, the timing will be reset upon signal is re- triggered. Timing Range: 0.1 seconds (min.) ~ 999 minutes (max.) continuously adjustable How to choose a timing range: Upon setting the parameter value in the mode selection interface, select the timing range by short pressing the STOP button. XXX. Decimal point at single digit, timing range = 1 second ~ 999 seconds. XX.X Decimal point at tens digit. timing range = 0.1 second ~ 99.9 seconds X.X.X. All the decimal points appear, timing range = 1 minute ~ 999 minutes. For example, if you want to set the OP to 3.2 seconds, then move the decimal point to the tenth digit, the digital tube displays 03.2 Parameter explanation: OP = on time, CL = off time, LOP = cycle times (1 - 999 times, "---" stands for infinite cycles) These parameters are independent each other, while they are shared by all operation modes. For example, when the OP(on- time) is set to 5 seconds in P1.1, the user wants P1.2 mode, then enter P1.2 to set the corresponding parameters, OP will also be 5 seconds. In the main interface (digital tube displays 000), short press SET button, it will show OP (CL, LOP) and the corresponding time XXX - If there is only OP (such as mode P1.1, P1.2, P1.3) time in the mode, then short press SET button will only display OP and the corresponding time. - If there are OP, CL, LOP in the mode (such as mode P3.1, P3.2), short press SET button will display OP and corresponding time, CL and corresponding time, LOP and corresponding times. After setting the operation mode, you can easily view and change the parameters by pressing the SET button in the main interface. How to Set Parameters 1. First of all, determine the working mode of the relay. 2. Upon the working mode of the relay, in the main interface (when the module is powered on, it will flash the current working mode - default P1.1 mode, and then enter the main interface) Long press the SET button for 2 seconds and release to enter the mode selection interface, select and set the mode (P1.1 ~ P-4) by short pressing the UP and DOWN buttons. 3. Select a setting mode you want (Eg. P3.2), short press SET button to set the parameter. At that time, the parameter you set will flash (OP - ON time, CL - OFF time, LOP - cycle number). You could adjust the parameter by pressing UP and DOWN button. Long press (increase or reduce rapidly) and short press (increase or decrease by 1 unit) are supported. After setting the parameter, select the position of units point by short pressing “STOP” button to choose a timing range (corresponding time 0.1 seconds~999 minutes). Short press “SET” button to set the next parameter of current mode, the progress is as what have mentioned above. 4. After selecting the mode’s parameter, long press the “SET” button for 2 seconds and release. The current setting mode will flash and return to the main interface, and the parameter setting is finished. It’s very simple! Main interface: It will appear “000” without decimal points when at “OFF” status, while appears decimal points clearly at “ON” status. Mode selecting interface: Long press “SET” button to set parameter, while long press “SET” button to return back to the main interface. It’s very simple! Relay Using Mode: 1. ON: Relay is allowed to conduct within OP time (on-time). 2. OFF: Relay is banned conducting and it is always at closing status. Short pressing “STOP” button in the main interface, you will realize the shift between “ON” and “OFF”. It will flash and return to the main interface. (This is acute stop function, one- button turn on and off the relay) Sleep Mode: 1. C-P sleeping mode: When not using the relay for 5 minutes, the digital tube will turn off the display automatically, and the program will keep working. 2. O-d normal mode: Display of digital tube always on. Long press “STOP” button for 2 seconds and release to shift the status of C-P and O-d. It will flash and return to the main interface. Package List: 2 x DC 6-30V Timer Relay Module with LED display (paper manual not included)

Product Features

  • Multifunction Timer RelayProgrammable delay modes to control the relay timings, widely used at smart home, industrial control, automatic irrigation, indoor ventilation, protection equipment etc.
  • Load RangeOperating voltage: DC 6V - 30V, support micro USB 5V power supply. High level trigger: 3V - 24V. NO(Normally open) maximum load < AC 250V/10A, < DC 30V/10A. Timing range: 0.1s ~ 999mins (continuously adjustable).
  • Reverse ProtectionBuilt-in a diode to provide protection against accidental reverse polarity for the circuits.
  • Sleep ModeIf no operation within 5 minutes, the digital tube of the relay board will turn off automatically. Pressing any button can wake it up.
  • Parameter SettingOP(conduction time) / CL(off time) / LOP(circuit times) can be set individually, and the parameters are mutually independent. All parameters are permanently saved once set. The functions and parameters can be reviewed or changed at a later time.