Enter 5DINGO at Checkout for 5% OFF & Free Shipping Australia Wide

{"id":12633363808416,"title":"Busch-Jaeger MCN316 LS switch 3P 6kA C-16A 3M screw technology","handle":"busch-jaeger-mcn316-ls-switch-3p-6ka-c-16a-3m-screw-technology","description":"\u003ch3\u003eBusch-Jaeger MCN316 LS switch 3P 6kA C-16A 3M screw technology\u003c\/h3\u003e \u003cp id=\"b\"\u003eProduct descriptions Important note: Please note that electrical work is only carried out by qualified electricians or under their direction and supervision may. If necessary, please note any different country-specific standards and regulations for electrical installation and seek advice from a local electrician. Devices with a connection value \u0026gt; 380V\/400V require a high-voltage connection and may only be connected by an approved electrician. For devices with a rated power \u0026gt; 12KW you need the consent of your network operator (Germany, other countries may vary). Circuit breaker 3-pole. C-16A, 6kA MCN316 tripping characteristic C, number of poles (total) 3, number of fused poles 3, rated current 16A, rated voltage 400V, rated insulation voltage Ui 500V, rated impulse withstand voltage Uimp 4kV, rated switching capacity Icn according to EN 60898 at 400 V 6kA, voltage type AC, frequency 50 ... 60Hz, energy limitation class 3, suitable for flush-mounted installation, overvoltage category 3, pollution degree 2, additional equipment possible, width in division units 3, installation depth 70mm, protection class (IP) IP20, ambient temperature during operation -25 ... 70°C, Connectable conductor cross-section, multi-wire 1 ... 25mm², connectable conductor cross-section, solid 1 ... 35mm², circuit breaker 3-pole 6kA C characteristic 16A 3 modules. Circuit breaker according to E DIN EN 60898-1 (VDE 0641-11), touch protection IP2x according to DIN VDE 0106 part 100 with VDE symbol. LS with time-delayed thermal release for overload protection and electromagnetic release for short-circuit protection. Suitable for retrofitting additional equipment. Possibility of labeling directly on the device and individual removal from the phase rail network by unlocking the quick fastening of the top-hat rail. Legal information Private sale, no returns or guarantee.\u003c\/p\u003e \u003ch3\u003eProduct Features\u003c\/h3\u003e \u003cul class=\"a\"\u003e \u003cli\u003eFor line protection according to DIN VDE 0641 Part 11, 3-pole 230\/400 V\/AC\u0026lt; \/li\u0026gt;\u003c\/li\u003e\n\u003c\/ul\u003e","published_at":"2024-03-06T02:07:01+11:00","created_at":"2024-03-06T02:07:03+11:00","vendor":"Busch-Jaeger","type":"Circuit breaker","tags":["industryDE"],"price":22200,"price_min":22200,"price_max":22200,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":48962359460000,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"de-B000ONIHC6","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Busch-Jaeger MCN316 LS switch 3P 6kA C-16A 3M screw technology","public_title":null,"options":["Default Title"],"price":22200,"weight":180,"compare_at_price":null,"inventory_management":"shopify","barcode":"MCN316","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/dingoship.com.au\/cdn\/shop\/files\/de-B000ONIHC6.jpg?v=1709685320"],"featured_image":"\/\/dingoship.com.au\/cdn\/shop\/files\/de-B000ONIHC6.jpg?v=1709685320","options":["Title"],"media":[{"alt":null,"id":32666551255200,"position":1,"preview_image":{"aspect_ratio":1.0,"height":2000,"width":2000,"src":"\/\/dingoship.com.au\/cdn\/shop\/files\/de-B000ONIHC6.jpg?v=1709685320"},"aspect_ratio":1.0,"height":2000,"media_type":"image","src":"\/\/dingoship.com.au\/cdn\/shop\/files\/de-B000ONIHC6.jpg?v=1709685320","width":2000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eBusch-Jaeger MCN316 LS switch 3P 6kA C-16A 3M screw technology\u003c\/h3\u003e \u003cp id=\"b\"\u003eProduct descriptions Important note: Please note that electrical work is only carried out by qualified electricians or under their direction and supervision may. If necessary, please note any different country-specific standards and regulations for electrical installation and seek advice from a local electrician. Devices with a connection value \u0026gt; 380V\/400V require a high-voltage connection and may only be connected by an approved electrician. For devices with a rated power \u0026gt; 12KW you need the consent of your network operator (Germany, other countries may vary). Circuit breaker 3-pole. C-16A, 6kA MCN316 tripping characteristic C, number of poles (total) 3, number of fused poles 3, rated current 16A, rated voltage 400V, rated insulation voltage Ui 500V, rated impulse withstand voltage Uimp 4kV, rated switching capacity Icn according to EN 60898 at 400 V 6kA, voltage type AC, frequency 50 ... 60Hz, energy limitation class 3, suitable for flush-mounted installation, overvoltage category 3, pollution degree 2, additional equipment possible, width in division units 3, installation depth 70mm, protection class (IP) IP20, ambient temperature during operation -25 ... 70°C, Connectable conductor cross-section, multi-wire 1 ... 25mm², connectable conductor cross-section, solid 1 ... 35mm², circuit breaker 3-pole 6kA C characteristic 16A 3 modules. Circuit breaker according to E DIN EN 60898-1 (VDE 0641-11), touch protection IP2x according to DIN VDE 0106 part 100 with VDE symbol. LS with time-delayed thermal release for overload protection and electromagnetic release for short-circuit protection. Suitable for retrofitting additional equipment. Possibility of labeling directly on the device and individual removal from the phase rail network by unlocking the quick fastening of the top-hat rail. Legal information Private sale, no returns or guarantee.\u003c\/p\u003e \u003ch3\u003eProduct Features\u003c\/h3\u003e \u003cul class=\"a\"\u003e \u003cli\u003eFor line protection according to DIN VDE 0641 Part 11, 3-pole 230\/400 V\/AC\u0026lt; \/li\u0026gt;\u003c\/li\u003e\n\u003c\/ul\u003e"}

Busch-Jaeger MCN316 LS switch 3P 6kA C-16A 3M screw technology

In Stock. Leaves warehouse within 2 - 3 business days

222.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

Busch-Jaeger MCN316 LS switch 3P 6kA C-16A 3M screw technology

Product descriptions Important note: Please note that electrical work is only carried out by qualified electricians or under their direction and supervision may. If necessary, please note any different country-specific standards and regulations for electrical installation and seek advice from a local electrician. Devices with a connection value > 380V/400V require a high-voltage connection and may only be connected by an approved electrician. For devices with a rated power > 12KW you need the consent of your network operator (Germany, other countries may vary). Circuit breaker 3-pole. C-16A, 6kA MCN316 tripping characteristic C, number of poles (total) 3, number of fused poles 3, rated current 16A, rated voltage 400V, rated insulation voltage Ui 500V, rated impulse withstand voltage Uimp 4kV, rated switching capacity Icn according to EN 60898 at 400 V 6kA, voltage type AC, frequency 50 ... 60Hz, energy limitation class 3, suitable for flush-mounted installation, overvoltage category 3, pollution degree 2, additional equipment possible, width in division units 3, installation depth 70mm, protection class (IP) IP20, ambient temperature during operation -25 ... 70°C, Connectable conductor cross-section, multi-wire 1 ... 25mm², connectable conductor cross-section, solid 1 ... 35mm², circuit breaker 3-pole 6kA C characteristic 16A 3 modules. Circuit breaker according to E DIN EN 60898-1 (VDE 0641-11), touch protection IP2x according to DIN VDE 0106 part 100 with VDE symbol. LS with time-delayed thermal release for overload protection and electromagnetic release for short-circuit protection. Suitable for retrofitting additional equipment. Possibility of labeling directly on the device and individual removal from the phase rail network by unlocking the quick fastening of the top-hat rail. Legal information Private sale, no returns or guarantee.

Product Features

  • For line protection according to DIN VDE 0641 Part 11, 3-pole 230/400 V/AC< /li>